COOLING SYSTEM
 
System P3
up to 20 bar coolant pressure


How does the BEMA P3 device work?


A device fitted to the side of the milling head with four coolant outlet nozzles, a device that can be radially positioned at any angle. The particular position is regulated by remote control. No more reaching into running machines.


P3 consists of the following:
  • manual rotating potentiometer
  • mains switch
  • 220V connection

Swivel-mounted coolant nozzles consist of the following:
  • coolant nozzles
  • servo motor
  • coolant connector

Example of throughflow quantities
per individual nozzle:


3,2 mm 2 bar pressure
3 bar pressure
4 bar pressure
07 l/min
09 l/min
10 l/min
5,0 mm 2 bar pressure
3 bar pressure
4 bar pressure
18 l/min
22 l/min
25 l/min
6,5 mm 2 bar pressure
3 bar pressure
4 bar pressure
30 l/min
35 l/min
42 l/min
9,0 mm 2 bar pressure
3 bar pressure
4 bar pressure
56 l/min
70 l/min
80 l/min


This progress comes to you from BEMA


   enlarging


   enlarging