COOLING SYSTEM
 
Manual system P05
up to 10 bar coolant pressure
 


How does the BEMA P05 device work?


A device fitted to the side of the milling head with one coolant outlet nozzle, a device that can be radially positioned at any angle. The particular position is regulated by remote control. No more reaching into running machines.


P05 consists of the following:
  • manual rotating potentiometer
  • mains switch
  • 220V connection

Swivel-mounted coolant nozzles consist of the following:
  • coolant nozzles
  • servo motor
  • coolant connection

Example of throughflow quantities
per individual nozzle:


3,2 mm 2 bar pressure
3 bar pressure
4 bar pressure
07 l/min
09 l/min
10 l/min
5,0 mm 2 bar pressure
3 bar pressure
4 bar pressure
18 l/min
22 l/min
25 l/min
6,5 mm 2 bar pressure
3 bar pressure
4 bar pressure
30 l/min
35 l/min
42 l/min
9,0 mm 2 bar pressure
3 bar pressure
4 bar pressure
56 l/min
70 l/min
80 l/min