Manual system P05
up to 10 bar coolant pressure |
|
How does the BEMA P05 device work?
A device fitted to the side of the milling head with one coolant outlet nozzle, a device that can be radially positioned at any angle. The particular position is regulated by remote control. No more reaching into running machines.
P05 consists of the following:
- manual rotating potentiometer
- mains switch
- 220V connection
Swivel-mounted coolant nozzles consist of the following:
- coolant nozzles
- servo motor
- coolant connection
Example of throughflow quantities per individual nozzle:
|
| 3,2 mm |
2 bar pressure 3 bar pressure 4 bar pressure |
07 l/min 09 l/min 10 l/min |
| 5,0 mm |
2 bar pressure 3 bar pressure 4 bar pressure |
18 l/min 22 l/min 25 l/min |
| 6,5 mm |
2 bar pressure 3 bar pressure 4 bar pressure |
30 l/min 35 l/min 42 l/min |
| 9,0 mm |
2 bar pressure 3 bar pressure 4 bar pressure |
56 l/min 70 l/min 80 l/min |
|
|
|
|
|
|